← Our Services  /  Portable Fire Fighting Equipment

Fire Extinguishers

Supply, siting and annual servicing of portable fire extinguishers, matched to the fire risks present in your building. Based in Stockport, covering Greater Manchester, Cheshire and the Peak District, with sites across the UK.

Safety notice

The right extinguisher, in the right place, serviced on time. We select equipment against the fire classes present on site: A (solids), B (flammable liquids), C (gases), D (metals), Electrical, F (cooking oils/fats), and L (lithium-ion).

Selection and siting follow BS 5306‑8 — including travel distance and visibility — and every extinguisher is serviced annually to BS 5306‑3 by a competent engineer, with a record kept for your compliance file.

Viaduct Fire engineer in hard hat and hi-vis at the open rear of a van stocked with red fire extinguishers
STANDARD

BS 5306‑3 & BS 5306‑8

BS 5306‑8 covers selecting and siting portable extinguishers; BS 5306‑3 covers commissioning and maintenance, including annual servicing by a competent person. We keep a record of every service against your building for your compliance file.

Technical Specification

Fire classes.

Extinguisher provision is matched to the classes of fire actually present on site, not a one-size-fits-all count.

ClassCoversHow it is sized
AOrdinary combustibles — wood, paper, textiles, most general office and retail risk.From floor area: 0.065 × area in m², minimum 26A per storey. Maximum travel distance 30m.
BFlammable liquids — solvents, fuels, paints.Against the specific liquids, quantities and storage on site, not floor area. Maximum travel distance 10m.
CFlammable gases.Assessed for the specific site rather than given a fixed travel distance under the 2023 edition. See the safety notes below before providing any extinguisher for a gas risk.
DCombustible metals.Specialist assessment of the metal and process involved; standard extinguishers are not suitable.
ElectricalFires involving live electrical equipment. Use non-conductive media only — CO₂, non-conductive powder or a clean agent.Covered by the general 30m provision, or within 10m where an extinguisher is provided specifically for an electrical hazard.
FCooking oils and fats — commercial kitchens.From the surface area of the oil, using the Class F calculator. Maximum travel distance 10m.
LLithium-ion cells and battery packs (where no metallic lithium is present) — laptops, phones, power tools, e-bikes and scooters, battery storage. A new class, added by BS ISO 3941:2026.No extinguisher rating or provision rule exists for this class yet. Lithium-ion guidance below ↓

Work out your building's minimum Class A rating and count, or the right Class F extinguisher for a fryer: Fire Extinguisher Calculator.

Safety

The wrong extinguisher can make things worse.

Choosing an extinguisher is not just a box to tick. The wrong type, used on the wrong fire or in the wrong place, can spread a fire, injure the person using it, or turn a small incident into a serious one.

WATER · OIL

Water on cooking oil and fat

Water is heavier than oil. It sinks, boils violently and throws burning oil out of the pan, spreading the fire. Burning cooking oil and fat needs a Class F (wet chemical) extinguisher, or a fire blanket for a small pan fire — never a water extinguisher.

WATER · ELECTRICAL

Water on live electrical equipment

Water conducts electricity, so spraying it on live equipment puts the user at risk of electric shock. Use a non-conductive medium — CO₂, non-conductive powder or a clean agent — and isolate the power if it is safe to do so.

DRY POWDER

Dry powder indoors

A powder discharge fills the air with fine dust. Indoors, that cuts visibility and makes breathing difficult, which makes escape harder for you and everyone else, and the residue can ruin electronic equipment. Powder is generally kept out of buildings unless a risk assessment specifically justifies it.

CO₂

CO₂ in small or enclosed spaces

CO₂ works by displacing the oxygen around the fire. In a small room, store or other enclosed space it can displace the oxygen you are breathing too, and there is a risk of asphyxiation. The discharge horn also gets extremely cold — never hold it. Ventilate the area as soon as the fire is out.

GAS FIRES

Putting out a gas fire

If a gas flame is put out while the gas is still flowing, the gas keeps escaping and can build up into a flammable cloud that any spark or hot surface can ignite — a fire risk becomes an explosion risk. The first action is to isolate the gas supply, if that can be done safely. If it can’t, leave the building and call 999.

BOILER HOUSES

Gas plant rooms and boiler houses

Our advice is that extinguishers should only be provided in areas with gas — such as gas boiler houses — where the fire risk assessment specifically calls for them, and where on-site staff have been trained to deal with gas fires. Without both, the right response to a fire there is to evacuate, isolate the gas if it is safe to do so, and call 999.

General guidance only. The right provision for your building should come from your fire risk assessment and the current edition of BS 5306‑8.

Handle With Care

Know your extinguisher.

An extinguisher is a pressure vessel, and it is only as safe as its condition.

PRESSURE

Stored under pressure

Every extinguisher holds its contents under pressure. A CO₂ extinguisher is at around 55 bar (roughly 800 psi) at room temperature — compare that with a car tyre at up to about 2.5 bar. Take care when handling, moving or transporting extinguishers, never tamper with the valve or head, and where a gauge is fitted check it reads in the green.

CONDITION

Rust and damage can cause failure

Rust or corrosion on the cylinder or valve, and dents or other damage, can weaken the body. A weakened extinguisher under pressure can fail and seriously injure whoever is holding it. If an extinguisher shows any of these signs, take it out of use and have it inspected by a competent person.

MONTHLY CHECK

What to look for

Check that it is in its place and visible, the pin and tamper seal are intact, the hose and nozzle are not split or blocked, the gauge (if fitted) is in the green, the label is legible, and there is no rust, corrosion or physical damage. Report anything that has been used, even partly, so it can be refilled and serviced.

SERVICING

Annual service and longer overhauls

BS 5306‑3 recommends annual servicing by a competent person, with longer-interval overhauls and pressure testing as the extinguisher ages. We keep a record of every service against your building for your compliance file.

Extinguisher training for your staff

An extinguisher is only useful if the person holding it knows what it is, when to use it and when to leave. Get in touch to talk about training for your team.

Viaduct Fire’s Notes

Having them is not enough.

Our view, from the engineer’s side of the job.

Adequate extinguisher provision matters — the right types, in the right places, in good condition. But for most sites, training people to use them is just as important. An extinguisher in untrained hands is a gamble: staff can pick the wrong type for the fire in front of them, or tackle a fire they should have walked away from.

Good training teaches people to size up a fire and decide whether to fight it or leave, to choose the right extinguisher medium for the fire (and avoid the dangerous mismatches above), and to tackle it more effectively using the PASS technique:

P

Pull

Pull out the pin or safety clip so the extinguisher can be operated.

A

Aim

Aim the nozzle or hose at the base of the fire, not the flames. Technique differs a little between extinguisher types.

S

Squeeze

Squeeze the handle firmly to discharge the extinguisher.

S

Sweep

Sweep across the base of the fire to spread the contents over it, working from the front.

PASS is only the last step. Always make sure your escape route is behind you, and never tackle a fire you aren’t trained and confident to deal with — if in doubt, get out and call 999. Practical training is what turns PASS from a slogan into something people can do under pressure.

Ask About Training

Don’t forget the fire blanket

A fire blanket is a simple, low-cost addition wherever there is cooking. It smothers a small fire in a shallow pan or on a worktop by cutting off the oxygen, and it can be wrapped around a person whose clothing has caught fire. It is not for large fires, or for fires you can’t approach safely. Choose blankets that meet BS EN 1869, mount them where they can be reached without leaning over the hazard, and replace one after any use — manufacturers typically also recommend replacing unused blankets after five to seven years. We can include fire blankets in your provision and servicing visits.

All-class and service-free extinguishers

Viaduct Fire takes a holistic approach to every eventuality on a site, and that includes equipment that isn’t the conventional choice. Two kinds are worth knowing about.

Firexo All Class extinguishers are a single-unit answer to mixed risks. Firexo says the unit is suitable for fires of Classes A to F, including live electrical equipment and lithium-ion batteries, and retailers list it as BSI Kitemarked and certified to BS EN 3‑7. For a site with a mix of hazards that can simplify provision. Be aware that one extinguisher claiming every class does not change the dangers described above — in particular, it does not make it safe to put out a gas fire while the gas is still flowing — and that it still needs annual servicing to BS 5306‑3 and training for the people who would use it. Check the certification marks on the unit itself and confirm the details with the supplier.

P50 “service-free” extinguishers use a corrosion-resistant, non-metal body. The manufacturer offers a 10-year service-free life, with in-house monthly visual checks and an annual pressure check using the supplied magnet in place of the usual annual engineer visit. They can suit some situations well, such as damp or corrosive environments, but they cost more up front, there is no CO₂ version, and the “service-free” label is disputed in the industry: BS 5306‑3 is understood to still expect safety-critical checks on non-metal-bodied extinguishers, so confirm what applies to your site.

We would describe both as unconventional rather than typical choices. If you are considering them, check suitability with a competent person and confirm what your insurer expects before you buy. Get in touch and we will talk through whether they make sense for your site.

Lithium-ion fires: a grey area

In early 2026, BS ISO 3941 — the standard that classifies fires — added a new Class L for fires involving lithium-ion cells and battery packs. It recognises what makes them different: they can overheat and spread from cell to cell (thermal runaway), give off toxic gas, throw out parts of the battery, and re-ignite after the flames appear to be out.

What the new class did not bring is practical guidance. Class L is not part of the BS EN 2 / EN 3 system used to rate extinguishers, so no extinguisher carries a Class L rating, and the classification comes with no test method for extinguishers and no rules on how many to provide. BS 5306‑8:2023 does include guidance for small individual devices — a laptop, phone or power tool that is not charging — which, as BAFE summarises it, is to disconnect the power if it is safe to do so and cool the device with water or a water-based extinguisher. It does not cover multiple devices, or lithium-ion batteries in larger equipment such as e-bikes, e-scooters, vehicles or battery storage.

Extinguishers marketed for lithium-ion fires, including some all-class units, are tested by their manufacturers under controlled test conditions on small batteries, not in a real-world fire in a charging area or a flat, and not to a published standard. A draft standard, BS EN 3‑11, would set a common test for batteries up to 600 Wh, with flames out within three minutes and no re-ignition in the following 20 minutes, and a mandatory label warning that lithium-ion battery fires are extremely dangerous and that training is advised. It was still going through final approval in mid-2026.

Lithium-ion fires are extremely dangerous and volatile, and the position is still a grey area. For most people the safest response is the one the fire services give: get out, raise the alarm and call 999 rather than tackling the fire. There are many resources online and we encourage you to consider this carefully for your site — especially where batteries are charged or stored. Fire and rescue services publish guidance: London Fire Brigade — what to do if there’s a fire caused by an e-bike or e-scooter, and Greater Manchester Fire and Rescue Service — battery safety.

What's Included

Scope of work.

  • Fire risk-matched extinguisher selection (water, foam, CO2, dry powder, wet chemical)
  • Supply & wall-mounting to BS 5306‑8 siting rules
  • Annual servicing & certification
  • Signage
  • Replacement of expired, discharged or damaged units

Common Questions

Extinguisher FAQs.

  • What areas do you cover for fire extinguisher servicing?

    We're based in Stockport and service fire extinguishers across Greater Manchester, Cheshire and the Peak District, with cover further afield across the UK where needed.

  • How often do fire extinguishers need to be serviced?

    BS 5306‑3 recommends annual servicing by a competent person, alongside a basic visual check you can do in-house between visits. We keep a full service record against your building for your compliance file.

  • How do you decide which type of extinguisher I need?

    We assess the fire classes actually present on site — A (solids), B (flammable liquids), C (gases), D (metals), electrical, F (cooking oils/fats) and L (lithium-ion) — and select and site extinguishers to match, rather than taking a one-size-fits-all approach.

  • Does my fire extinguisher have to be red?

    Not by law, but the standard says it should be. BS EN 3 calls for a signal-red body with a label, band or circle covering at least 5% of the surface in a colour that shows what is inside the extinguisher. An extinguisher in another colour — a chrome or copper designer unit, for example — can still be used, but it does not conform to the standard, so it cannot carry the BSI Kitemark. Where you use non-standard extinguishers, your fire risk assessment should record why they are suitable, and your staff should be trained on them. Older extinguishers coloured all over remain legal until they need replacing, apart from green halon units, which are banned.

  • What happens when an extinguisher is due to expire or has been discharged?

    We flag any extinguisher that's due to expire, has been discharged, or fails inspection, and replace it as part of the same visit so your cover isn't left with a gap.

Other Specialisms

The rest of the picture.

Fire and security systems rarely stop at one discipline — here's everything else we cover.

FA‑SYS‑01 Fire Alarms icon

Fire Alarms

Design, installation, commissioning and maintenance of fire detection and alarm systems, specified to the layout and use of your building.

Fire Alarms →
EL‑SYS‑03 Emergency Lighting icon

Emergency Lighting

Emergency lighting that works when the power doesn't — designed, installed and tested to BS 5266‑1, so escape routes stay lit and exits stay visible.

Emergency Lighting →
CC‑SUR‑04 CCTV icon

CCTV

Camera systems specified to suit the site, with remote viewing options — from a single entrance camera to a fully networked, monitored setup.

CCTV →
IA‑DET‑05 Intruder Alarms icon

Intruder Alarms

Detection and alarm systems protecting premises against unauthorised access — from single-zone setups for smaller units to multi-zone systems across larger sites.

Intruder Alarms →
DS‑DOC‑06 Drawing Design icon

Drawing Design

Zone plans, system schematics and as-wired drawings for new and existing systems — available as a standalone service for systems that need documentation brought up to date.

Drawing Design →
AC‑SYS‑07 Access Control icon

Access Control

Card, fob and keypad access control systems, specified to release safely on activation of your fire detection system.

Access Control →
SM‑MON‑08 Sprinkler Monitoring icon

Sprinkler Monitoring

Electrical monitoring of wet and dry sprinkler installations — flow, valve position, tank level and pump status brought back to a dedicated monitoring panel, with the signals passed on to your fire alarm system and, where required, to an ARC.

Sprinkler Monitoring →
AR‑MON‑09 ARC Monitoring icon

ARC Monitoring

Signalling from fire and intruder alarms to an accredited Alarm Receiving Centre, with police URN application support for intruder alarms.

ARC Monitoring →