← Our Services  /  Intruder Detection & Alarm Systems

Intruder Alarms

Detection and alarm systems protecting premises against unauthorised access — from single-zone setups for smaller units to multi-zone systems across larger sites. Based in Stockport, covering Greater Manchester, Cheshire and the Peak District, with sites nationwide.

From single-zone setups for smaller units to multi-zone systems across larger sites. Where it's useful, systems can be set up with monitoring in mind, so an alert doesn't rely on someone being on-site to hear it.

Detection is specified to the site — wired or wireless, door contacts, PIRs, or a mix — designed, installed and commissioned to PD 6662, the UK scheme that applies the BS EN 50131 series, and graded to match the level of risk the building actually carries.

For premises that need more than an audible alert, we also arrange ARC monitoring and police URN registration, so a confirmed activation can qualify for a police response. That response is set by the NPCC policy, which states that it cannot be guaranteed, so we explain the conditions before you rely on it.

We're based in Stockport and install and maintain intruder alarm systems across Greater Manchester, Cheshire and the Peak District, with sites further afield across the UK.

Fig. 03 — Zone detection sweep (illustrative)

Technical Specification

System grades.

Grades 1–4 are defined in BS EN 50131-1, and PD 6662 applies them in the UK — the risk level a system is designed to resist, not just how many sensors it has.

GradeDesigned against
1Low risk — intruders with little knowledge of intruder alarm systems, using a limited range of easily available tools. Seldom specified; many insurers won’t accept a Grade 1 system where an alarm is a condition of cover.
2Low-to-medium risk — intruders with some knowledge of intruder alarm systems, using ordinary tools and portable instruments such as a multimeter. Domestic properties and lower-risk commercial premises, such as small shops and offices with few valuables on site.
3Medium-to-high risk — intruders familiar with intruder alarm systems, with a comprehensive range of tools and portable electronic equipment. The usual grade for commercial premises, and the one most insurers ask for when an alarm is a requirement of cover.
4High risk — intruders with the ability and resources to plan an attack in detail, including substituting components of the system. High-security sites such as banks, bullion stores and government premises; rarely needed commercially.

Full reference detail: Intruder Alarm Grades. A system’s overall grade is only as high as its lowest-graded component. The grade for your premises should come from a risk assessment and your insurer’s requirements.

Standards & Police Response

How a system is specified.

The standards set how a system is built and installed, and the police policy sets what has to be in place before a response is possible.

STD‑01

PD 6662 & BS EN 50131

BS EN 50131 is the European product and system series for intrusion and hold-up alarms, and PD 6662 is the UK scheme that applies it, covering the design, installation, commissioning and maintenance of a system. The 2017 edition, in force since 1 June 2019, uses undated references so that it picks up the current editions of the standards it calls up. NSI-approved companies issue a certificate of compliance for each commissioned system.

STD‑02

BS 8243 confirmation

BS 8243 covers the installation and configuration of intruder alarm systems designed to generate confirmed alarm conditions. Confirmation requires a second, separate trigger before the alarm is passed on, which reduces the number of false activations that reach the monitoring centre and the police. PD 6662 calls up BS 8243, and the police response policy requires it for new systems.

STD‑03

NPCC police response

The NPCC Security Systems Policy sets the conditions for a Unique Reference Number (URN). Installation and monitoring have to be certificated by a UKAS-accredited certification body, the alarm receiving centre has to meet BS 5979 Category II or BS EN 50518 with BS 8591, and the system has to be installed to the accepted standards, which for new systems means PD 6662:2017 with BS 8243. The policy states that response is determined by demand, priorities and resources at the time and cannot be guaranteed.

STD‑04

False calls & withdrawal

Under the March 2024 version of the NPCC policy, three false calls within a rolling twelve months take an intruder alarm to Level 3, where police response is withdrawn; hold-up alarms are withdrawn after two. Getting the system right at design stage, and working with the ARC and keyholders, is how a URN is kept.

What's Included

Scope of work.

  • Single & multi-zone system design
  • Wired & wireless detection
  • Monitoring/signalling options
  • Fault-finding on existing systems
  • Planned maintenance

Other Specialisms

The rest of the picture.

Fire and security systems rarely stop at one discipline — here's everything else we cover.

FA‑SYS‑01 Fire Alarms icon

Fire Alarms

Design, installation, commissioning and maintenance of fire detection and alarm systems, specified to the layout and use of your building.

Fire Alarms →
FE‑EQP‑02 Fire Extinguishers icon

Fire Extinguishers

Supply, siting and annual servicing of portable fire extinguishers, matched to the fire risks present in your building.

Fire Extinguishers →
EL‑SYS‑03 Emergency Lighting icon

Emergency Lighting

Emergency lighting that works when the power doesn't — designed, installed and tested to BS 5266‑1, so escape routes stay lit and exits stay visible.

Emergency Lighting →
CC‑SUR‑04 CCTV icon

CCTV

Camera systems specified to suit the site, with remote viewing options — from a single entrance camera to a fully networked, monitored setup.

CCTV →
DS‑DOC‑06 Drawing Design icon

Drawing Design

Zone plans, system schematics and as-wired drawings for new and existing systems — available as a standalone service for systems that need documentation brought up to date.

Drawing Design →
AC‑SYS‑07 Access Control icon

Access Control

Card, fob and keypad access control systems, specified to release safely on activation of your fire detection system.

Access Control →
SM‑MON‑08 Sprinkler Monitoring icon

Sprinkler Monitoring

Electrical monitoring of wet and dry sprinkler installations — flow, valve position, tank level and pump status brought back to a dedicated monitoring panel, with the signals passed on to your fire alarm system and, where required, to an ARC.

Sprinkler Monitoring →
AR‑MON‑09 ARC Monitoring icon

ARC Monitoring

Signalling from fire and intruder alarms to an accredited Alarm Receiving Centre, with police URN application support for intruder alarms.

ARC Monitoring →

Need intruder alarms?

Tell us about the site and what you need — we'll get back to you with a straight answer.