Intruder Alarm Grades

Grades 1–4 per PD 6662 / BS EN 50131 and the risk level each is designed to resist.

An intruder alarm’s grade describes how much resistance it is built to offer against an intruder of a given skill and toolset. The four grades come from BS EN 50131-1, and in the UK PD 6662 is the scheme that applies those standards. Ultimately, the grade a system needs should be settled at the design stage by a risk assessment, taking in your insurer’s requirements, and revisited whenever the building is extended, altered or its use changes.

GradeDesigned against (BS EN 50131-1)Typical examples
1Low risk — intruders with little knowledge of intruder alarm systems, using a limited range of easily available tools.Seldom specified. Many insurers won’t accept a Grade 1 system where an alarm is a condition of cover.
2Low‑to‑medium risk — intruders with some knowledge of intruder alarm systems, using ordinary tools and portable instruments such as a multimeter.Domestic properties and lower‑risk commercial premises, such as small shops and offices with few valuables on site.
3Medium‑to‑high risk — intruders familiar with intruder alarm systems, with a comprehensive range of tools and portable electronic equipment.The usual grade for commercial premises, and the one most insurers ask for when an alarm is a requirement of cover.
4High risk — intruders with the ability and resources to plan an attack in detail, including substituting components of the system.High‑security sites such as banks, bullion stores and government premises. Rarely needed commercially.

A system’s overall grade is only as high as its lowest‑graded component, so every detector, control panel and communicator needs to meet the grade you are aiming for. The “typical examples” above are guidance, not rules — your insurer’s wording and the risk assessment decide the grade for your site.

Police response: a Unique Reference Number (URN) comes from the local police force under the National Police Chiefs’ Council (NPCC) policy on police response to security systems. In general, the system must be professionally monitored by an alarm receiving centre, installed by a UKAS‑accredited company to PD 6662 / BS EN 50131, and use confirmation under BS 8243. Rules vary between forces and change from time to time, so always check the current position with us or your force before you rely on a police response. See our monitoring page for how we handle this.

Weighing this up alongside your fire safety obligations? See our guide: Are you the Responsible Person? →